• When this item is set to "Disable", system functions for the site will become unavailable if the Master
unit and/or Backup Master unit fails.
Default
Disable
Value Range
Enable, Disable
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration
—Slot—Site Property
PC Programming Manual References
1.2.3.1 One-look Networking Survivability
Feature Manual References
3.1.1 Backup Master Mode and Isolated Mode
Normal Mode Auto Recovery
Specifies
whether a Slave unit in Isolated mode automatically switches to Normal mode when the Master unit
recovers.
Default
Disable
Value Range
Disable, Enable
Maintenance Console Location
9.5 PBX Configuration—[1-1] Configuration—Slot—Site Property
Feature Manual References
3.1.1 Backup Master Mode and Isolated Mode
Switch Time Service to "Break" in Isolated Mode
Specifies whether to set the Time Service to Break mode when the PBX enters Isolated Mode.
Default
Disable
Value Range
Enable, Disable
236 PC Programming Manual Document Version 2016-03
9.5.1 PBX Configuration—[1-1] Configuration—Slot—Site Property—Main