EasyManua.ls Logo

Panasonic KX-NS1000 - 3.2.2.31 Subscriber Tutorial; 3.2.2.32 Timed Reminder Setting

Panasonic KX-NS1000
1294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIP 200 Response Timer (*100 ms)
Specifies
the amount of time to wait for a SIP 200 (OK) response when establishing a connection between two
parties. (Specifying "0" will disable the timer.)
Default
0
Value Range
0–18000 ´ 100 ms
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
SIP 18x Response Timer (s)
Specifies
the amount of time to wait for a 18x response when establishing a connection between two parties.
Default
110
Value Range
0–255 s
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Proxy-Require Option
Specifies
option tags in a Proxy-Require header field so that the SIP server is notified that the client is behind
a router with NAT enabled and firewall.
Default
Not stored
Value Range
Max. 100 characters
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Failover Timer(INVITE)
Specifies the amount of time to wait for a response for an INVITE request.
Default
0 s
Value Range
0–30 s
Document Version 2016-03 PC Programming Manual 311
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property

Table of Contents