IntelliCenter Control System User’s Guide
| 19
From the Schedule screen you can program On and Off times for circuits (AUX -
auxiliary and Feature circuits). Circuits can be scheduled set to turn On or Off all
days, weekends, weekdays, or any specific day of the week. Each 24 hour period,
equipment (lights, heater, spa jets, filter pump) can be programmed for multiple
On/Off times. You can also schedule which heat mode to use and also change the
heat set point if necessary. The Schedule screen lists each scheduled circuit(s)
start and stop time, and days to run.
One Time Only Timer: This schedule will switch equipment on for the specified
amount of time. You can set the desired One Time Only schedule to run the pump
for the specified time only.
Heater Cool Down: Default enabled. Provides a two minute-delay in turning off the
circulation pump after heater has completed its firing cycle to allow the heater to
cool down. See page 72 for more information.
Continue to next page.
Schedule
To access the Schedule screen, from Home screen tap Schedule: Select either
a Weekly, or One Time Only schedule. From the Schedule screen you can add,
delete, edit, enable and disable schedules. Tap the Add button (+) to add a
schedule. To delete a program, tap the program from the list. Tap the Trash Can
icon to delete the program from the list.