Tap pH to select the pH setting screen.
ph Reading/Set Point/Tank: Displays
the current pH level reading. Tap the
Set Point Up/Down button to adjust
the pH set point value. The adjustable
range is from 7.2 to 7.6 in increments
of 0.1. The default pH set point value
is 7.5.
Tank: Tap the tank segment (1-6) to
match the amount of muriatic acid
currently in the canister. The canister
can hold a maximum of 3-1/2 gals. of
muiatic acid.
The Tank indicator (1-6 segment) is a
visual representation of the amount of
muriatic acid currently in the external
canister. Tap the Up or Down button to
match the amount of muriatic acid in
the canister.
IntelliChem Chemistry Controller Screen: Tap Up arrow to view Page 2 of 2.
To view the (IntelliChem) Chemistry Summary screen tap the Chemistry icon
on the Home screen. Tap the UP arrow on the screen to display the next page
(Page 2 of 2) to view the Pool Output and Spa Output chlorine percentage values.
If an IntelliChlor SCG is installed, tap the Up arrow on the screen to display the
IntelliChlor SCG screen. To add an IntelliChem and/or IntelliChlor device to the
system, see Advanced System configuration > Installation Setup > Chemistry , on
page 78. Note: To display pH and ORP readings on Home screen Chemistry Icon,
see Settings > General > Chemistry Readings Badge(Set to ON). See page 45.
pH Value
pH value is the measurement of the acidity (0 to 7) or alkalinity (7 to 14) of the pool
water. The pH low and high alarm set point values are preset at the factory to 6.7
and 7.9. For a pool, the advised ideal pH is between 7.2 - 7.8 (a pool professional
should regularly check the water for metal presence, cyanuric acid levels and TDS
(total dissolved solids). To maintain accurate pH pool water measurements, regular
maintenance of the pH probe is advisable. pH probe calibration is necessary before
the summer season.