Alteon Application Switch Operating System Application Guide
Accessing Alteon
48 Document ID: RDWR-ALOS-V2900_AG1302
Configuring SNMP Trap Hosts
This section describes how to configure the following SNMP trap hosts:
• SNMPv1 Trap Host, page 48
• SNMPv2 Trap Host, page 49
• SNMPv3 Trap Host, page 49
SNMPv1 Trap Host
To configure an SNMPv1 trap host
1. Configure a user with no authentication and password.
2. Configure an access group and group table entries for the user. Use the nview command to
specify which traps can be received by the user. In the following example, the user receives the
traps sent by Alteon:
3. Configure an entry in the notify table.
4. Specify the IP address and other trap parameters in the targetAddr and targetParam tables.
Use the uname command to specify the user name used with this targetParam table.
>> # /cfg/sys/ssnmp/snmpv3/usm 10 name "v1trap"
>> # /cfg/sys/ssnmp/snmpv3/access 10
>> SNMPv3 vacmAccess 10 # name "v1trap"
>> SNMPv3 vacmAccess 10 # model snmpv1
>> SNMPv3 vacmAccess 10 # nview "iso"
>> # /cfg/sys/ssnmp/snmpv3/group 10
>> SNMPv3 vacmSecurityToGroup 10 # model snmpv1
>> SNMPv3 vacmSecurityToGroup 10 # uname v1trap
>> SNMPv3 vacmSecurityToGroup 10 # gname v1trap
>> # /cfg/sys/ssnmp/snmpv3/notify 10
>> SNMPv3 vacmSecurityToGroup 10 # name v1trap
>> SNMPv3 vacmSecurityToGroup 10 # tag v1trap
>> # /cfg/sys/ssnmp/snmpv3/taddr 10
(Access the TargetAddrTable
menu)
>> SNMPv3 snmpTargetAddrTable 10 # name v1trap
>> SNMPv3 snmpTargetAddrTable 10 # addr 50.80.23.245
>> SNMPv3 snmpTargetAddrTable 10 # taglist v1trap
>> SNMPv3 snmpTargetAddrTable 10 # pname v1param
>> # /cfg/sys/ssnmp/snmpv3/tparam 10
(Access the TargetParamsTable
menu)
>> SNMPv3 snmpTargetParamsTable 10 # name v1param
>> SNMPv3 snmpTargetParamsTable 10 # mpmodel snmpv1
>> SNMPv3 snmpTargetParamsTable 10 # uname v1trap
>> SNMPv3 snmpTargetParamsTable 10 # model snmpv1

Table of Contents

Other manuals for Radware Alteon

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radware Alteon and is the answer not in the manual?

Radware Alteon Specifications

General IconGeneral
ModelAlteon
ManufacturerRadware
LayerLayer 4-7
TypeApplication Delivery Controller (ADC)
FeaturesLoad balancing, SSL offloading, application acceleration, DDoS protection
Form FactorVirtual Appliance