MIB Parameters Appendix Q
WinLink™ 1000 User Manual Release 1.9 Q-10
winlink1000OduAirRssBalance 1.3.6.1.4.1.4458.1000.1.5.49 Integer RO RSS balance. Relation between RSS in radio 1
and RSS in radio 2.
winlink1000OduAirTotalTxPower 1.3.6.1.4.1.4458.1000.1.5.50 Integer RO Total Transmit Power in dBm. This is a nominal
value While the actual transmit power includes
additional attenuation.
winlink1000OduAirInstallFreqAndCBW 1.3.6.1.4.1.4458.1000.1.5.51 DisplayString RW Installation frequency
winlink1000OduAirDFStype 1.3.6.1.4.1.4458.1000.1.5.52 Integer RO DFS regulation type.
winlink1000OduAirComboSubBandTable N/A ODU Multi-band Sub Bands Table.
winlink1000OduAirComboSubBandEntry N/A ODU Multi-band Sub Bands Table entry. INDEX {
winlink1000OduAirComboSubBandIndex }
winlink1000OduAirComboSubBandIndex RO ODU Multi-band sub bands table index.
winlink1000OduAirComboSubBandId RO Represents the Multi-band sub band ID.
winlink1000OduAirComboSubBandDescr
iption
RO Multi-band sub band description.
winlink1000OduAirComboSubBandInstall
Freq
RO Represents the Multi-band sub band installation
frequency in KHz.
winlink1000OduAirComboSubBandAdmi
nState
RO Represents the Multi-band sub band
administrative state.
winlink1000OduAirComboSubBandInstall
ationAllowed
RO Reflects if the Multi-band sub band allowes
installtion.
winlink1000OduAirComboNumberOfSub
Bands
1.3.6.1.4.1.4458.1000.1.5.53.2 Integer RO Represents the number of Multi-band sub bands.
winlink1000OduAirComboSwitchSubBan
d
1.3.6.1.4.1.4458.1000.1.5.53.3 DisplayString RW Switch sub band operation with a given sub band
ID. The get operation retrieves the current sub
band ID.
winlink1000OduAirInternalMaxRate RO Max Ethernet throughput of the site (in Kpbs).
winlink1000OduAirCapacityDirection RW Capacity direction of the site.
winlink1000OduPerfMonCurrTable N/A This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonCurrEntry N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
winlink1000OduPerfMonCurrUAS 1.3.6.1.4.1.4458.1000.1.6.1.1.1 Gauge RO The current number of Unavailable Seconds
starting from the present 15 minutes period.
winlink1000OduPerfMonCurrES 1.3.6.1.4.1.4458.1000.1.6.1.1.2 Gauge RO Current number of Errored Seconds starting from
the present 15 minutes period.
winlink1000OduPerfMonCurrSES 1.3.6.1.4.1.4458.1000.1.6.1.1.3 Gauge RO Current number of Severely Errored Seconds
starting from the present 15 minutes period.
winlink1000OduPerfMonCurrBBE 1.3.6.1.4.1.4458.1000.1.6.1.1.4 Gauge RO Current number of Background Block Errors
starting from the present 15 minutes period.
winlink1000OduPerfMonCurrIntegrity 1.3.6.1.4.1.4458.1000.1.6.1.1.5 Integer RO Indicates the integrity of the entry.
winlink1000OduPerfMonIntervalTable N/A This table defines/keeps the counters of the last
day (in resolution of 15 min intervals).
winlink1000OduPerfMonIntervalEntry N/A This is an entry in the Interval Table. INDEX
{ifIndex
winlink1000OduPerfMonIntervalIdx RO This table is indexed per interval number. Each
intervalis of 15 minutes and the oldest is 96.
winlink1000OduPerfMonIntervalUAS RO The current number of Unavailable Seconds per
interval.
winlink1000OduPerfMonIntervalES RO Current number of Errored Seconds per interval.
winlink1000OduPerfMonIntervalSES RO Current number of Severely Errored Seconds per
interval.
winlink1000OduPerfMonIntervalBBE RO Current number of Background Block Errors per
interval.
Table Q-2: Private MIB Parameters (Sheet 6 of 14)
Name OID Type
Access
Description