MIB Parameters Appendix Q
WinLink™ 1000 User Manual Release 1.9 Q-11
winlink1000OduPerfMonIntervalIntegrity RO Indicates the integrity of the entry per interval.
winlink1000OduPerfMonDayTable N/A This table defines/keeps the counters of the
current 15 min interval.
winlink1000OduPerfMonDayEntry N/A This is an entry in the Days Table. INDEX {ifIndex
winlink1000OduPerfMonDayIdx RO This table is indexed per interval number. Each
intervalis of 24 hours and the oldest is 30.
winlink1000OduPerfMonDayUAS RO The current number of Unavailable Seconds per
interval of 24 hours.
winlink1000OduPerfMonDayES RO Current number of Errored Seconds per interval of
24 hours.
winlink1000OduPerfMonDaySES RO Current number of Severely Errored Seconds per
interval of 24 hours.
winlink1000OduPerfMonDayBBE RO Current number of Background Block Errors per
interval of 24 hours.
winlink1000OduPerfMonDayIntegrity RO Indicates the integrity of the entry per interval of 24
hours.
winlink1000OduPerfMonAirCurrTable N/A This table defines/keeps the air counters of the
current 15 min interval.
winlink1000OduPerfMonAirCurrEntry N/A This is an entry in the Current Interval Table.
INDEX {ifIndex }
winlink1000OduPerfMonAirCurrMinRSL 1.3.6.1.4.1.4458.1000.1.6.4.1.1 Integer RO Current Min Received Level Reference starting
from the present 15 minutes period.
winlink1000OduPerfMonAirCurrMaxRSL 1.3.6.1.4.1.4458.1000.1.6.4.1.2 Integer RO Current Max Received Level Reference starting
from the present 15 minutes period.
winlink1000OduPerfMonAirCurrRSLThre
sh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.3 Gauge RO Number of seconds Receive Signal Level
exceeded the RSL1 threshold in the last 15
minutes.
winlink1000OduPerfMonAirCurrRSLThre
sh2Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.4 Gauge RO Number of seconds Receive Signal Level
exceeded the RSL2 threshold in the last 15
minutes.
winlink1000OduPerfMonAirCurrMinTSL 1.3.6.1.4.1.4458.1000.1.6.4.1.5 Integer RO Current Min Transmit Signal Level starting from
the present 15 minutes period.
winlink1000OduPerfMonAirCurrMaxTSL 1.3.6.1.4.1.4458.1000.1.6.4.1.6 Integer RO Current Max Transmit Signal Level starting from
the present 15 minutes period.
winlink1000OduPerfMonAirCurrTSLThre
sh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.7 Gauge RO Number of seconds Transmit Signal Level
exceeded the TSL1 threshold in the last 15
minutes.
winlink1000OduPerfMonAirCurrBBERThr
esh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.1.8 Gauge RO Number of seconds Background Block Error Ratio
exceeded the BBER1 threshold in the last 15
minutes.
winlink1000OduPerfMonAirIntervalTable N/A This table defines/keeps the air counters of the last
day (in resolution of 15 min intervals).
winlink1000OduPerfMonAirIntervalEntry N/A This is an entry in the Interval Table. INDEX
{ifIndex
winlink1000OduPerfMonAirIntervalIdx RO This table is indexed per interval number. Each
intervalis of 15 minutes and the oldest is 96.
winlink1000OduPerfMonAirIntervalMinRS
L
RO Current Min Received Level Reference per
interval.
winlink1000OduPerfMonAirIntervalMaxR
SL
RO Current Max Received Level Reference per
interval.
winlink1000OduPerfMonAirIntervalRSLT
hresh1Exceed
RO Number of seconds Receive Signal Level
exceeded the RSL1 threshold per interval.
winlink1000OduPerfMonAirIntervalRSLT
hresh2Exceed
Number of seconds Receive Signal Level
exceeded the RSL2 thresholdACCESS read-only
per interval.
Table Q-2: Private MIB Parameters (Sheet 7 of 14)
Name OID Type
Access
Description