Remote Control
R&S
®
FSPN
359User Manual 1179.4363.02 ─ 01
Manual operation: See "Defining the signal frequency" on page 106
See "Searching for a signal" on page 107
See "Defining the frequency range of the measurement"
on page 133
[SENSe:]FREQuency:STARt <Frequency>
This command defines the start frequency offset of the measurement range.
Parameters:
<Frequency> Offset frequencies in half decade steps.
Range: See data sheet
*RST: 1 kHz
Default unit: Hz
Example: //Define a start offset of 10 kHz
FREQ:STAR 10KHZ
Example: //Define a span of 500 MHz from 500 MHz to 1 GHz
FREQ:STAR 500MHZ
FREQ:STOP 1GHZ
Manual operation: See "Defining the measurement range" on page 108
See "Defining the frequency range of the measurement"
on page 133
[SENSe:]FREQuency:STOP <Frequency>
This command defines the stop frequency offset of the measurement range.
Parameters:
<Frequency> Offset frequencies in half decade steps.
Range: See data sheet
*RST: 1 MHz
Default unit: Hz
Example: //Define a stop offset of 10 MHz
FREQ:STOP 10MHZ
Example: //Define a span of 500 MHz from 500 MHz to 1 GHz
FREQ:STAR 500MHZ
FREQ:STOP 1GHZ
Manual operation: See "Defining the measurement range" on page 108
See "Defining the frequency range of the measurement"
on page 133