CALCulate<n>[:RANGe<j>]:EVALuation:WEIGhting <Name>
This command selects a weighting filter whose values are applied to the calculation of
residual effects.
Suffix:
<n>
.
Window
<j> Integration range
Setting parameters:
<Name> String containing the name of the filter.
*RST: NONE
Example: //Apply a weighting filter to the residual calculations in integration
range 1
CALC:RANG1:EVAL:WEIG 'A FILTER'
Manual operation: See "Applying weighting filters" on page 117
[SENSe:]CORRection:WEIGhting:COMMent
<Name>
This command defines a comment for a weighting filter whose values are applied to
the calculation of residual effects.
Setting parameters:
<Name> String containing the comment.
Example: See [SENSe:]CORRection:WEIGhting:NAME on page 371.
Manual operation: See "Designing weighting filters" on page 118
[SENSe:]CORRection:WEIGhting:DATA {<freq>, <level>}...
This command defines the shape of the weighting filter whose values are applied to the
calculation of residual effects.
The shape of the weighting filter is defined by two or more pairs of frequency and level
values.
Parameters:
<freq> <numeric value>
Default unit: Hz
<level> <numeric value>
Default unit: dB
Example: See [SENSe:]CORRection:WEIGhting:NAME on page 371.
Manual operation: See "Designing weighting filters" on page 118
[SENSe:]CORRection:WEIGhting:DELete
This command deletes the currently selected weighting filter.
Common Measurement Settings