12-4 srellortnoC evirD 30EVIRDOCEtenibaC lortnoC eht gnitcurtsnoC
0
40
80
120
160
200
240
280
320
360
400
440
480
04020
I [A]
Pv [W]
P
V
: Power dissipation
I: Current (Sine threshold value)
Fig. 12-6: Determining power dissipation in the control cabinet for each drive
controller DKC**.3-100-7-FW without braking resistor power with
4 kHz
0
40
80
120
160
200
240
280
320
360
400
440
480
0 10 20 30
I [A]
Pv [W]
P
V
: Power dissipation
I: Current (Sine threshold value)
Fig. 12-7: Determining power dissipation in the control cabinet for each drive
controller DKC**.3-100-7-FW without braking resistor power with
8 kHz
DKC**.3-100-7-FW
4 kHz
DKC**.3-100-7-FW:
8 kHz