RFL 9780 16 - 3 RFL Electronics Inc.
April 8, 2003 (973) 334-3100
NOTE
The prompt will be 9780TxRx> for a TxRx chassis, 9780TxTx> for a TxTx chassis,
9780RxRx> for an RxRx chassis, 9780Tx> for a Tx Only chassis, and 9780Rx> for an Rx Only
chassis.
To view a list of the APRIL commands, press the [H] and [ENTER] keys:
9780 TxRx >H [ENTER]
This tells the RFL 9780 to send a list of APRIL commands called the "main menu" to your terminal.
The main menu appears in Figure 16-3.
RFL Electronics APRIL(t) Remote Communications, Version 2.1 (c)1993,1999
H - Display the main menu
V - Go to the values display
P - Go to the programming menu (password required)
D - Go to the read settings menu
F - Go to the configuration and software version display
U - Enter the update mode
X - Exit the update mode
S - Go to sequence of events menu
9780TxRx>
Figure 16-3. APRIL main menu
For more information on each APRIL command, refer to the paragraph numbers listed below.
Command Meaning Paragraph
H Display the main menu 16.3
V Go to the values display 16.5
P Go to the programming menu (password) 16.6
D Go to the read settings menu 16.7
F Go to the configure and software version display 16.8
U Enter the update mode 16.9
X Exit the update mode 16.9
S Go to sequence-of-events menu 16.10
W Window remote April 16.11