EasyManua.ls Logo

Ricoh S-C3 F - Page 119

Ricoh S-C3 F
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No.
Definition
Symptom Possible Cause/Countermeasure
The unexpected error occurs when the
modem (Cumin-M) tries to call the center
with a dial up connection.
Software bug.
-002 D
Program execution error
Same as SC651-001. Software bug.
670 B
Engine startup error
Just after the main power is turned on or
the machine is recovering from auto off
mode, the engine ready signal assertion
fails.
Just after the main power is turned on, the
engine does not respond.
Poor connection between the BICU
and controller board
Defective BICU
Defective controller board
672 B
Controller-to-operation panel communication error at startup
After powering on the machine,
communication between the controller
and operation panel does not begin, or
the communication is interrupted after a
normal startup.
Controller stalled
Controller board installed incorrectly
Defective controller board
Operation panel connector loose or
defective
Poor connection of DIMM and
optional boards on the controller
board
1. Check the setting of SP5875-001. If
the setting is set to "1 (OFF)", change
it to "0 (ON)".
SC8xx
No.
Definition
Symptom Possible Cause/Countermeasure
819 Kernel stop
[0696e] B
Process error
4. Troubleshooting
118
4

Table of Contents