44 Basic Operation ODIN Intercom Matrix
For A Redundant Connection
IMPORTANT: IFL connection redundancy does not mean the frame and its setup is redundant. Only the connection
between frames is protected from cable failure.
1. On the rear panel of frame 1, connect one end of an IFL cable to the PRI DOWNLINK connector.
2. Connect the other end of the IFL cable to the PRI UPLINK connector on the rear panel of frame 2.
3. Using a second IFL cable, connect one end of the IFL cable to the SEC DOWNLINK connector on frame 1.
4. Connect the other end of the IFL cable to the SEC UPLINK connector on frame 2.
5. Using a third IFL cable, connect one end of the IFL cable to the PRI DOWNLINK connector on frame 2.
6. Connect the other end of the second IFL cable to the PRI UPLINK connector on frame 3.
7. Using a fourth IFL cable, connect one end of the IFL cable to the SEC DOWNLINK connector on frame 2.
8. Connect the other end of the IFL cable to the SEC UPLINK connector on frame 3.
9. Repeat steps 5 through 8 for additional frames (maximum eight frames).
10. On the last frame, connect one end of an IFL cable to the PRI DOWNLINK connector.
11. Connect the other end of the IFL cable to the PRI UPLINK connector on frame 1.
12. On the last frame, connect one end of an IFL cable to the SEC DOWNLINK connector.
13. Connect the other end of the IFL cable to the PRI UPLINK connector on the frame 1.