153
The setting range varies depending on the print resolution of the product.
The setting range of the label width is as follows:
Resolution S84NX S86NX
203 dpi
(1 dot = 0.125 mm
(0.0049"))
1 to 832 dots 1 to 1340 dots
305 dpi
(1 dot = 0.083 mm
(0.0033"))
1 to 1248 dots 1 to 2010 dots
609 dpi
(1 dot = 0.042 mm
(0.0017"))
1 to 2496 dots -
• Set the label size to a value that includes the liner.
[Auto Measure]
The product automatically measures the length of the media.
The measured length of the media will be automatically saved in [Label Length].
The Auto Measure function can be performed when [Sensor Type] is set to [Gap] or [I-Mark].
The setting procedure of the label length using the Auto Measure function is as follows:
1. Load the media.
2. Set [Auto Measure] to [Enabled].
3.
Press the button or button to show the Online or Offline screen.
4. Open the print head. (Head Open error occurs.)
5. Close the print head. (The display returns to Offline screen.)
6.
When you press the button, the product feeds two pieces of label and measures the label
length.
7. The measured label length is saved in [Label Length].
• When you enable [Auto Measure], this function executes in the following conditions:
◦ The first time the product changes to Online mode after being powered on
◦ When the product changes to Online mode after the top cover is opened/closed
◦ When the product changes to Online mode after the settings in the [Sensor Type]
menu are changed