161
Standard/Left-Hand Type Opposite/Right-Hand Type
(8) Base reference point after adjustment
[Advanced]
Set detailed sensor operation and print motion.
The setting items are as follows:
[Calibrate]
Adjust the media sensor level.
In instances of media detection malfunction, adjust the media sensor level (Gap and I-mark sensors).
The setting items are as follows:
[Auto-calibration]
Perform the auto-calibration for the selected media sensor.
[Auto-calibration] is not available if you have selected [Linerless] in the [Print Mode].
Gap + I-Mark
Adjusts both the Gap sensor and I-mark sensor.
Gap
Adjusts the Gap sensor.
I-Mark
Adjusts the I-mark sensor.
The procedure to auto-calibrate the media sensor is as follows:
1. Open the top cover.
2. Turn the head lock lever clockwise to unlock the print head, and then pull the feed lock latch to
unlock the feed roller and media sensor assembly.
3. Load the media.
Remove the label from the liner and set the liner so the I-mark is not above the I-mark sensor.