Left - Right Pressure Balance Setting
370
4. Loosen the screw (3) attached to the adjust collar (2).
Do not remove the screw.
5. Turn the adjust collar (2) to adjust the head pressure balance.
Turn the adjust collar counterclockwise to increase the head pressure on the frame side.
Turn the adjust collar clockwise to increase the head pressure on the opposite side.
• If the product orientation is opposite from the image, the adjustment direction is
reversed.