Protection parameter group 06
PARAMETER DESCRIPTION 109
Group
Parameter
Number
Name
Setting Range
Default
Page
06-27
P.292
Total inverter operation time
(minutes)
01439 min
0min
115
06-28
P.293
Total inverter operation time
(days)
09999 day
0day
115
06-29
P.296
Total inverter power on time
(minutes)
01439 min
0min
115
06-30
P.297
Total inverter power on time (days)
09999 day
0day
115
06-40
P.288
Alarm record code query
Choose 012 recorded alarm
0
116
06-41
P.289
Alarm record code display
Read only
Read only
116
06-42
P.290
Alarm record message query
Choose 010 recorded alarm
0
116
06-43
P.291
Alarm record message display
Read only
Read only
116
06-84
P.207
Fire mode
XXX0:Invalid(the fire mode is
forbidden(normal mode))
0
117
XXX1:Forward operation(the inverter runs
forward in fire mode)
XXX2:Reverse operation( the inverter runs
reversely in fire mode)
0XXX:Manually exit fire mode 1 ( if the start
fire mode terminal is OFF, the inverter need
reset manually and back to normal mode)
1XXX:Exit fire mode automatically (if the start
fire mode terminal is OFF, the inverter goes
to normal mode automatically)
2XXX Manually exit fire mode 2(if the start
fire mode terminal is OFF, the inverter keeps
running, need reset manually and back to
normal mode)
06-85
P.208
Frequency setting in fire mode
0~650.00Hz
60.00Hz
117
06-88
P.209
Accumulated times in fire mode
Read only
Read only
117

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SC3 Series and is the answer not in the manual?

Shihlin electric SC3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSC3 Series
CategoryInverter
LanguageEnglish

Related product manuals