Definitions of terminologies
MANUAL GUIDE 10
1.3 Definitions of terminologies
Output frequency, target frequency, steady output frequency
The actual output current frequency of inverter is called “output frequency.”
The frequency set by user (via built-in keypad, multi-speed terminals, voltage signal, and current signal or
communication settings) is called “target frequency.”
When motor starts running, inverter output frequency will gradually accelerate to target frequency before it
finally runs steadily at the target frequency. This output frequency is called “steady output frequency.”
Parameter settings
Detail explanation on parameter settings are provided in Chapter 5. For users who are not familiar with these
settings, arbitrary adjustment of the parameter may result in abnormal operations.All parameters can be reset to
their default values by the parameter 00-02(P.996~P.999). For setting procedures of this parameter, please refer
to 00-02(P.996~P.999) in Section 5.1.2.
The “operation mode” and “working mode” of the built-in keypad
Target frequency command source and start signal source depend on inverter operation mode. There are
nine operating modes in Shihlin inverter. Please refer to Section 4.3 for details.
Built-in keypad is used mainly for monitoring the numeric values, setting parameters and target frequency.
Please refer to Section 4.2 for details.
The difference between “terminal name” and “function name”:
Printed letters can be found near the terminals on control board and main board. They are used to distinguish
each terminal and are called “terminal name.”
For “multi-function control terminal” and “multi-function output terminal,” besides the terminal name, it is also
necessary to define the “function name.” The function name indicates the actual functions of the terminal.
When explaining the function for a terminal, the name used is its “function name”.
The difference between “on” and “turn on”:
When explaining the function for the “multi-function digital input terminal”, two words “on” and “turn on” are
often used:
The word “on” is used to indicate that the external switch of the terminal is in close state, and thus it belongs
to the description of the state.
The word “turn on” is used to describe the action that the external switch of the terminal is shut from the open
state to the close state, and thus belongs to the description of action. Similarly, the words off” and “turn off"
belong to the above-mentioned states and actions.
P.XXX
P.XXX refers to parameter number, not page number.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SC3 Series and is the answer not in the manual?

Shihlin electric SC3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSC3 Series
CategoryInverter
LanguageEnglish

Related product manuals