Application parameter group 10
PARAMETER DESCRIPTION 146
5.10.4 Restart mode selection
Select suitable start mode according to different load conditions.
Parameter
Name
Default
Setting Range
Content
10-08
P.150
Restart mode
selection
0
X0
No frequency search.
X1
Reserved
X2
Decrease voltage mode
0X
Power on once.
1X
Start each time.
2X
Only instantaneous stop and restart
3X
Only valid when the inverter resets in fire mode
10-09
P.57
Restart idling time
99999
030.0s
---
99999
Off.
10-10
P.58
Restart rising time
5.0s
060.0s
7.5K/11KF and below model
10.0s
11K/15KF and above model
Restart mode selection
10-08(P.150) is set by 2 bits. The meaning of each bit is as follows:
10-08P.150 =
0No frequency search.
1Reserved
2Decrease voltage
mode
0Power on once
1Start each time
2Only instantaneous stop and restart
3Only valid when the inverter resets
in fire mode
Restart
During motor operation, when instantaneous power interruption occur inverter will stop output immediately. If
10-09 (P.57) =99999, inverter will not restart automatically after power is restored; If 10-09(P.57)=0.1~30, when
power is restored, inverter will automatically restart the motor after idling for a period of time (10-09(P.57) value).
When restarting the motor automatically, output frequency is target frequency, but output voltage is zero and then
slowly rises to the proper voltage value. This voltage rise time is called “Restart rising time (10-10(P.58))”.
Instantaneous (power failure) time
Power supply
(R/L1S/L2T/L3)
Motor speed N
(r/min)
Inverter output
frequency f (Hz)
Inverter output
voltage E (v)
Restart cushion time
10-10(P.58) setting
Coasting time 10-
09(P.57)setting
*
* The output shut off timing differs
according to the load condtion
Time
Time
Time
Time
Note:1. 10-08(P.150) must also be set if need instant restart function.
2. If 10-08(P.150) is not 0, in default inverter do linear acceleration and deceleration.
3. This function is only valid under V/F control, that is, it is valid when 00-21 (P.300)=0
Setting
Setting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SC3 Series and is the answer not in the manual?

Shihlin electric SC3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSC3 Series
CategoryInverter
LanguageEnglish

Related product manuals