Basic Parameter Group 01
PARAMETER DESCRIPTION 71
5.2.7 JOG run
The frequency and acceleration/deceleration time for JOG running can be set. JOG can be used for conveyor
positioning, test run, etc.
Parameter
Name
Default
Setting Range
Content
01-13
P.15
JOG frequency
5.00Hz
0650.00Hz
---
01-14
P.16
JOG Acc/ Dec time
0.50s
0360.00s/
03600.0s
01-08(P.21)=0/
01-08(P.21)=1
JOG operation
In JOG mode, the output frequency is the set value of 01-13(P.15), and the acceleration / deceleration time is the
set value of 01-14(P.16).
01-03(P.15)
01-09(P.20 )
01-14
(P.16 )
01-09(P.20 )
01-14
(P.16 )
Forward
Reverse
ON
ON
FWD
REV
Time
Output
frequency
01-03(P.15)
Note:1. Please refer to Section 4.3.3 Basic operation steps for JOG mode for how to enter the JOG mode.
Setting

Table of Contents