System parameter group 00
PARAMETER DESCRIPTION 52
5.1.3 Parameter protection
It is used to select whether parameters can be written to prevent changing parameter values due to misoperation.
Parameter
Name
Default
Setting Range
Content
00-03
P.77
Selection of
parameters write
protection
0
0
Parameters can be written only when the motor stops.
1
Parameters cannot be written.
2
Parameters can also be written when the motor is
running.
3
Parameters cannot be read when in password protection.
00-04
P.294
Password parameter
0
0~65535
Write the registered password to decrypt parameter
protection.
00-05
P.295
Password setup
0
2~65535
Register password for parameter protection setting.
Selection of parameters write protection
Write parameters only during stop (00-03(P.77)=“0”initial value)
Exception
When running, the parameters below can still be written:
Group
No.
Name
Group
No.
Name
00-03
P.77
Selection of parameters write protection
04-05
P.26
Speed 6
00-07
P.161
Multi-function display
04-06
P.27
Speed 7
02-25
P.198
Terminal 3-5 minimum input current/
voltage
04-07
P.142
Speed 8
02-26
P.199
Terminal 3-5 maximum input current/
voltage
04-08
P.143
Speed 9
02-27
P.196
Percentage corresponds to terminal 3-5
minimum input current/ voltage
04-09
P.144
Speed 10
02-28
P.197
Percentage corresponds to terminal 3-5
maximum input current/ voltage
04-10
P.145
Speed 11
02-52
P.56
Inverter rated current display level
04-11
P.146
Speed 12
04-00
P.4
Speed 1 (high speed)
04-12
P.147
Speed 13
04-01
P.5
Speed 2 (medium speed)
04-13
P.148
Speed 14
04-02
P.6
Speed 3 (low speed)
04-14
P.149
Speed 15
04-03
P.24
Speed 4
04-19
P.131
Programmed operation mode speed 1
04-04
P.25
Speed 5
04-20
P.132
Programmed operation mode speed 2
04-21
P.133
Programmed operation mode speed 3
06-40
P.288
Alarm record code query
04-22
P.134
Programmed operation mode speed 4
06-42
P.290
Alarm record message query
04-23
P.135
Programmed operation mode speed 5
08-03
P.225
PID target value
04-24
P.136
Programmed operation mode speed 6
08-18
P.223
Analog feedback signal bias
04-25
P.137
Programmed operation mode speed 7
08-19
P.224
Analog feedback signal gain
04-26
P.138
Programmed operation mode speed 8
10-19
P.230
Dwell frequency at acceleration
06-17
P.261
Maintenance alarm function
10-21
P.232
Dwell frequency at deceleration
10-46
P.268
Voltage stall level
Setting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SC3 Series and is the answer not in the manual?

Shihlin electric SC3 Series Specifications

General IconGeneral
BrandShihlin electric
ModelSC3 Series
CategoryInverter
LanguageEnglish

Related product manuals