Communication parameter group 07
PARAMETER DESCRIPTION 134
Table for parameter recovery
Communication p
parameter (Note 1)
User registered
parameter
Note: 1. Communication P parameters includes 07-02(P.32), 07-00(P.33), 07-01(P.36), 07-03(P.48)~ 07-09(P.53),
00-16(P.79), 07-10(P.153) and 07-07(P.154).
2. Table 1 and table 2 refer to Section 5.1.2 table1 and table 2
3.“o”means that parameter can be restored to default value or error can be cleared.
4.“x”means that parameter or error cannot be cleared.
Special monitor code table
Monitor digital input terminal state.
Monitor digital output terminal state.
Monitor voltage across terminal 3-5
Monitor electronic thermal accumulation rate
Inverter temperature rising accumulation rate
Inverter NTC temperature accumulation
Motor electronic thermal accumulation rate
PID control target pressure
PID control feedback pressure
Note: 1. Digital input terminal state details
2. Digital output terminal state details