4 Project planning
4.1 Manufacturer of the machine
DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
Use of the safety laser scanner requires a risk assessment. Check whether addi‐
tional protective measures are required.
Comply with the applicable national regulations derived from the application (e.g.,
work safety regulations, safety rules, or other relevant safety guidelines).
Apart from the procedures described in this document, the components of the
safety laser scanner must not be opened.
The safety laser scanner must not be tampered with or changed.
Improper repair of the protective device can lead to a loss of the protective
function. The protective device must only be repaired by the manufacturer or by
someone authorized by the manufacturer.
4.2 Operator of the machine
DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
Changes to the electrical integration of the safety laser scanner in the machine
control and changes to the mechanical mounting of the safety laser scanner
necessitate a new risk assessment. The results of this risk assessment may
require the entity operating the machine to meet the obligations of a manufac‐
turer.
Changes to the device’s configuration may impair the protective function. The
effectiveness of the protective device must be checked after any change to the
configuration. The person carrying out the change is also responsible for maintain‐
ing the protective function of the device.
Apart from the procedures described in this document, the components of the
safety laser scanner must not be opened.
The safety laser scanner must not be tampered with or changed.
Improper repair of the protective device can lead to a loss of the protective
function. The protective device must only be repaired by the manufacturer or by
someone authorized by the manufacturer.
PROJECT PLANNING 4
8025220/1L9Q/2023-08-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherCA
25
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK EtherCAT microScan3 and is the answer not in the manual?

SICK EtherCAT microScan3 Specifications

General IconGeneral
Scanning angle275°
InterfacesEtherCAT
Protection classIP65
Supply voltage24 V DC
Resolution for protective field30 mm
Operating voltage24 V DC
Scanning range5.5 m
Number of fields128
Number of monitoring cases128
Response time30 ms
Operating temperature0 °C to 50 °C
Field of applicationIndustrial safety
Light sourceInfrared laser, 905 nm
Connection typeM12
Weight1.2 kg

Related product manuals