Protective field and reference contour field for access protection
If t
he reference contour represents the edge of the protected opening, its distance
from the protective field must not exceed 100mm. A distance equal to the
TZ value is recommended for high availability and sufficient protection. (TZ =
tolerance zone of the safety laser scanner, see "Data sheet", page 160.)
If the reference contour does not represent the edge of the protected opening, the
protective field must be larger than the protected opening. The required overrun
(o) is calculated using the same formula as for hazardous point protection.
1 2
Figure 25: Tolerance band of the contour as reference field (protective field within the protected
opening, edge of the protected opening = reference contour)
1
Tolerance band of the reference contour field
2
Distance of the protective field from the reference contour, to ensure availability
4.3.5 Monitoring case switching time
When switching between monitoring cases, it is possible that a person may already be
in t
he newly activated protective field when switching takes place. Only switching in time
(namely before the danger arises for the person at this location) ensures protection.
DANGER
H
azard due to lack of effectiveness of the protective device
Switching of the monitoring case should be timed so that the safety laser scanner
detects a person in the protective field with a sufficient minimum distance, before
the dangerous state occurs.
4 PROJECT PLANNING
32
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherCA 8025220/1L9Q/2023-08-14 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK EtherCAT microScan3 and is the answer not in the manual?

SICK EtherCAT microScan3 Specifications

General IconGeneral
Scanning angle275°
InterfacesEtherCAT
Protection classIP65
Supply voltage24 V DC
Resolution for protective field30 mm
Operating voltage24 V DC
Scanning range5.5 m
Number of fields128
Number of monitoring cases128
Response time30 ms
Operating temperature0 °C to 50 °C
Field of applicationIndustrial safety
Light sourceInfrared laser, 905 nm
Connection typeM12
Weight1.2 kg

Related product manuals