User name
T
he optional user name helps later users to find a contact for the application.
Enter a user name.
Application image
An ima
ge helps to identify the application more quickly. The application image is saved
in the project file on the PC and transmitted to the device. The Safety Designer sup‐
ports the following file formats: BMP, GIF, JPG, PNG, TIF.
1. Click on the pencil icon.
2. Select an image file for the application.
The image is incorporated as a thumbnail.
Description
A de
scription makes it easier to understand an application’s context more quickly.
Enter a description with a maximum of 1000characters.
7.8 Protocol settings
7.8.1 EtherCAT FSoE configuration
FSoE Slave Address
In or
der to identify an FSoE device in the network, a unique FSoE address in the 1
to 65,535 range is required. You assign the FSoE address to the device in Safety
Designer. Enter the same address in the safety project of the control.
Enter FSoE address.
7 C
ONFIGURATION
96
O P E R A T I N G I N S T R U C T I O N S | microScan3 – EtherCA 8025220/1L9Q/2023-08-14 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK EtherCAT microScan3 and is the answer not in the manual?

SICK EtherCAT microScan3 Specifications

General IconGeneral
Scanning angle275°
InterfacesEtherCAT
Protection classIP65
Supply voltage24 V DC
Resolution for protective field30 mm
Operating voltage24 V DC
Scanning range5.5 m
Number of fields128
Number of monitoring cases128
Response time30 ms
Operating temperature0 °C to 50 °C
Field of applicationIndustrial safety
Light sourceInfrared laser, 905 nm
Connection typeM12
Weight1.2 kg