Name Use Data type Definition Values Safety implica‐
t
ion
SafeCutOffPath02
…
S
afeCutOffPath08
Safety function BOOL Cut-off path 02 … 08
(safety-oriented)
The signal is ON if the
currently monitored
field in the cut-off path
is safety-related and
free.
1)
0 = OFF state,
protective field
interrupted
Safety-relevant
parameter
1 = ON state,
pr
otective field
free
NonsafeCutOffPath01 Additional func‐
t
ion
BOOL Cut-off path 01 (Not
safety-related)
The signal is ON if the
currently monitored
field in the cut-off path
is free.
0 = OFF state,
field interrupted
Parameter with‐
out safety impli‐
cation
1 = ON state,
field free
NonsafeCutOffPath02
…
N
onsafeCutOffPath08
Additional func‐
tion
BOOL Cut-off path 02 … 08
(Not safety-related)
The signal is ON if the
currently monitored
field in the cut-off path
is free.
1)
0 = OFF state,
field interrupted
Parameter with‐
out safety impli‐
cation
1 = ON state,
field free
Current Monitoring Case No
(
Table 1)
Diagnostics USINT Current monitoring
case (Monitoring case
table 1)
Signalizes the current
(active) monitoring case
of monitoring case
table 1.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of t
he current
(active) monitor‐
ing case
ResetRequiredCutOffPath01 Diagnostics BOOL Reset required, Cut-off
pa
th 01
Signalizes whether the
device is waiting for a
reset signal to switch
safety-related cut-off
path 01 to the ON
state.
0 = reset not
required
Parameter with
implication for
the safety func‐
tion
1= reset required
ResetRequiredCutOffPath02
…
R
esetRequiredCutOffPath08
Diagnostics BOOL Reset required, Cut-off
path 02 … 08
Signals whether the
device is waiting for a
reset signal to switch
the respective safety-
related cut-off path to
the ON state.
1)
0 = reset not
required
Parameter with
implication for
the safety func‐
tion
1= reset required
StandbymodeActive Diagnostics BOOL Status sleep mode
S
ignalizes whether the
device is in sleep
mode.
0 = device not in
sleep mode
Parameter with‐
out safety impli‐
cation
1 = device in
sleep mode
ContaminationWarning Diagnostics BOOL Contamination warning
Optics cover is dirty.
Clean the optics cover.
0 = no contami‐
nation warning
Parameter with‐
out safety impli‐
cation
1 = contamina‐
tion warning
ContaminationError Diagnostics BOOL Contamination error
Optics cover is dirty. All
safety outputs in the
OFF state. Clean the
optics cover.
0 = no contami‐
nation error
Parameter with
implication for
the safety func‐
tion
1 = contamina‐
tion error
TECHNICAL DATA 13
8021913/15ZW/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – EFI-pro
165