Operation
7.1 Operation
SINAMICS DCP
170 Operating Instructions, 09/2019, A5E34382853K
Copy drive data set
Set parameter p0819 as follows:
1. p0819[0] = Number of the drive data set to be copied (source)
2. p0819[1] = Number of the drive data set to which the data is to be copied (target)
3. p0819[2] = 1
Copying is started.
Copying is finished when p0819[2] = 0.
Function diagrams (see SINAMICS DCP List Manual)
8560 Command Data Sets (CDS)
8565 Drive Data Sets (DDS)
Overview of important parameters (see the SINAMICS DCP List Manual)
p0170 Command data set (CDS) number
p0809 Copy Command Data Set (CDS)
p0810 BI: Command Data Set, CDS bit 0
p0819 copy Drive Data Set (DDS)
p0820 BI: Drive Data Set selection DDS bit 0
p0821 BI: Drive Data Set selection DDS bit 1