Operation
7.1 Operation
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
175
7.1.2.2 Display and operation with the BOP20
Characteristics
Status display
Changing the active drive object
Displaying/changing parameters
Displaying/acknowledging faults and alarms
SINAMICS DCP controlled by the BOP20
Status display
The status display for each drive object can be set using p0005 and p0006.
Using the status display, you can switch to the parameter display or to a different drive
object. The following functions are supported:
Changing the active drive object
Press the "FN" and "Arrow up" keys -> the drive object number at the top left flashes
Select the required drive object using the arrow keys
Confirm with the "P" key
Parameter display
Press the "P" key
The required parameter can be selected using the arrow keys
Press the "FN" key -> parameter r0000 is displayed
Press the "P" key -> returns to the status display