Operation
7.1 Operation
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
175
7.1.2.2 Display and operation with the BOP20
Characteristics
● Status display
● Changing the active drive object
● Displaying/changing parameters
● Displaying/acknowledging faults and alarms
● SINAMICS DCP controlled by the BOP20
Status display
The status display for each drive object can be set using p0005 and p0006.
Using the status display, you can switch to the parameter display or to a different drive
object. The following functions are supported:
● Changing the active drive object
– Press the "FN" and "Arrow up" keys -> the drive object number at the top left flashes
– Select the required drive object using the arrow keys
– Confirm with the "P" key
● Parameter display
– Press the "P" key
– The required parameter can be selected using the arrow keys
– Press the "FN" key -> parameter r0000 is displayed
– Press the "P" key -> returns to the status display