Operation
7.16 Diagnostics
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
365
7.16.3 Faults and alarms
7.16.3.1 General information
Description
The faults and states detected by the individual components of the drive unit are indicated by
messages.
The messages are categorized into faults and alarms.
Note
The individual faults and alarms are described in Chapter "Faults and alarms" in the
SINAMICS
DCP List Manual. Here you can also find a section titled "Function diagrams"
"Faults and alarms", which contains function diagrams for the fault buffer, alarm b
uffer, fault
trigger, and fault configuration.
Properties of faults and alarms
Faults
Are identified by Fxxxxx
Can lead to a fault reaction
Must be acknowledged once the cause has been remedied
Status via Control Unit and LED RDY
Status via PROFIdrive status signal ZSW1.3 (fault active).
Entry in the fault buffer
Alarms
Are identified by Axxxxx
Have no further effect on the drive unit
Are automatically reset once the cause has been corrected. No acknowledgment is
required.
Status via PROFIdrive status signal ZSW1.7 (alarm active).
Entry in the alarm buffer
General properties of faults and alarms
Can be configured (e.g. change fault to alarm, fault reaction)
Triggering on selected messages possible
Initiation of messages possible via an external signal
Contains the component number for identifying the SINAMICS component involved
Contains diagnostic information on the message involved