EasyManua.ls Logo

Siemens sinamics dcp - 7.5.4.1 Setpoint assignment in the subscriber

Siemens sinamics dcp
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
7.5 Communication via PROFIBUS DP
SINAMICS DCP
232 Operating Instructions, 09/2019, A5E34382853K
Requirements
The following requirements should be observed for the "direct data exchange" function:
STARTER as of Version 4.2
Configuration:
Drive ES Basic, Drive ES SIMATIC or Drive ES PCS7 as of Version 5.3 SP3
Alternatively using a GSD file
The maximum number of process data per drive can be identified from the value in r2050
minus the resources that have already been used
A maximum of 16 links to publishers
Applications
For example, the following application can be implemented using the "slave-to-slave
communication" function:
Specifying binector connections from another slave
7.5.4.1 Setpoint assignment in the subscriber
Information about setpoints
Number of setpoint
When bus communication is being established, the master signals the slave the number
of setpoints (process data) to be transferred using the configuring telegram (ChkCfg).
Contents of the setpoints
The structure and contents of the data are determined using the local process data
configuration for the "SINAMICS slave".
Operation as "standard" slave
The drive unit (slave) only receives its setpoints as output data from the master.
Operation as subscriber
When a slave is operated as a subscriber, some of the setpoints are defined by one or
more publishers rather than by the master.
The slave is informed of the assignment via the parameterization and configuration
telegram when bus communication is being established.

Table of Contents

Other manuals for Siemens sinamics dcp

Related product manuals