7.4.6.2 PROFIBUS-based diagnostics
For communication via PROFIBUS, in the case of fault the following diagnostics data is
output:
Standard diagnostics (Page 216)
Identifier-related diagnostics (Page 216)
Status messages/module status (Page 217)
Channel-related diagnostics (Page 218)
Data sets DS0/DS1 and diagnostics alarm (Page 219)
Message structure
The following applies if a message contains all of the specified diagnostics data:
Standard diagnostics
Is always located at the beginning of the message.
Data sets DS0/DS1 and diagnostics alarm
Is always located at the end of the message. This message part is always slot-specific.
The actual state of the slot responsible for the message is always transferred in the
message.
The other diagnostics data (types) can be in any sequence. This is the reason that the
following diagnostics data include a header:
Identifier-related diagnostics
Status messages/module status
Channel-related diagnostics
The diagnostic data type can be uniquely identified based on the header.
Note
The master must operate in the DPV1 mode.