Operation
7.19 Drive Control Chart (DCC)
SINAMICS DCP
382 Operating Instructions, 09/2019, A5E34382853K
7.19.4 Backing up the DCC diagrams
A DCC project comprises two parts.
1. Information about the type, time slices and interconnection of the DCB blocks
2. Information about the layout and graphics in the DCC charts
When downloading the DCC chart to the drive (download to the target system), only the
information about the type, time slices and interconnection of the DCB blocks (Point 1) are
downloaded to the drive.
The DCC charts can also be saved in the target device by selecting the option Store
additional data on the target device. This is recommended if the DCC charts will also be
opened by another PG.
A further prompt appears after selecting the "Download to Target System" window. The DCC
charts are also saved when both checkboxes are activated.
The following prompt appears when selecting "Load to PG" later:
If the checkbox is activated, the DCC charts in the project are overwritten by those in the
target device.
The information about layout and graphics in the DCC charts (Point 2) is still available in the
STARTER project.