7.8 Communication via EtherNet/IP (EIP)
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
305
7.8.4 Configuration of a Rockwell controller with SINAMICS DCP
Note
Th
e user must have basic knowledge of Allen-Bradley / Rockwell PLCs.
The associated Allen
-Bradley / Rockwell documentation should be used for detailed
information about communication with EtherNet/IP and general programming of Rockwell
PLCs.
A "Generic Ethernet/IP" module must be created in order to communicate with a SINAMICS
DCP.
The following configurations must be made for the basic communication:
Selection of the module, figures "Selection of the module (1), (2) and (3)"
The dialog box for the selection of the module for the appropriate EtherNet interface is
selected in the I/O configuration through > right-click > New Module.
Figure 7-49 Selection of the module (1)