Operation
7.8 Communication via EtherNet/IP (EIP)
SINAMICS DCP
304 Operating Instructions, 09/2019, A5E34382853K
5 get,
get_and_cle
ar
UINT32 Alignment Errors Structure received, which does not match the
number of octets
UINT32 FCS Errors Structure received, which does not pass the FCS
UINT32 Single Collisions Structure successfully transmitted, precisely one
UINT32 Multiple Collisions Structure successfully transmitted, several colli-
First transmission attempt delayed
UINT32 Late Collisions Number of collisions that occurred delayed by
512 bit timers to the request
UINT32 Excessive Collisions Transmission unsuccessful as a result of inten-
UINT32 MAC Transmit Errors Transmission unsuccessful as a result of an in-
ternal MAC sublayer transmission error.
UINT32 Carrier Sense Errors Number of errors when attempting to send a
request frame, where the transmission condition
was lost or was not assigned
UINT32 MAC Receive Errors Transmission unsuccessful as a result of an in-
ternal MAC sublayer receive error.
6 get, set
UINT16 Control Bits -
11 get - Interface Capability Bit 0: Manual setting
Bit 1: Auto negotiate
Bit 2: Auto MDIX
Bit 3: Manual speed/duplex
Bits 4 – 31: reserved
Rest: Speed/Duplex options