Operation
7.8 Communication via EtherNet/IP (EIP)
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
303
Link Object, Class code F6 hex
Table 7- 68 Link Object – supported services
Class
Instance
Get Attribute single
Table 7- 69 Link Object – Class Attributes
Table 7- 70 Link Object – Instance Attributes
1 get UINT32 Interface Speed 0: link down,
10: 10 Mbps,
2 get - Interface Flags Bit 1: Link-Status
Bit 2: Duplex Mode (0: half duplex, 1 duplex)
bit 3 … 5: Automatic state identification
Bit 6: Reset required
Bit 7: Local hardware fault (0 = ok)
r8935 Ethernet MAC address
4 get,
get_and_cle
ar
Struct of Interface Counters Optional, required if the "Media Counters Attrib-
Received non-Unicast packets
Incoming packets, not processed
Incoming packets with errors
Incoming packets with unknown protocol
UINT32 Out Octets Sent octets
Outgoing packets, not processed
Outgoing packets, with errors