Operation
7.8 Communication via EtherNet/IP (EIP)
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
303
Link Object, Class code F6 hex
Table 7- 68 Link Object – supported services
Environment
Service
Class
Get Attribute all
Get Attribute single
Instance
Get Attribute all
Get Attribute single
Set Attribute single
Table 7- 69 Link Object – Class Attributes
Attribute ID
Service
Type
Name
1
get
UINT16
Revision
2
get
UINT16
Max Instance
3
get
UINT16
Num of Instances
Table 7- 70 Link Object – Instance Attributes
Attribute ID
Service
Type
Name
Value/explanation
1 get UINT32 Interface Speed 0: link down,
10: 10 Mbps,
100: 100 Mbps
2 get - Interface Flags Bit 1: Link-Status
Bit 2: Duplex Mode (0: half duplex, 1 duplex)
bit 3 … 5: Automatic state identification
Bit 6: Reset required
Bit 7: Local hardware fault (0 = ok)
3
get
ARRAY
Physical Address
r8935 Ethernet MAC address
4 get,
get_and_cle
ar
Struct of Interface Counters Optional, required if the "Media Counters Attrib-
ute" is implemented.
UINT32
In Octets
Received octets
UINT32
In Ucast Packets
Received Unicast packets
UINT32
In NUcast Packets
Received non-Unicast packets
UINT32
In Discards
Incoming packets, not processed
UINT32
In Errors
Incoming packets with errors
UINT32
In Unknown Protos
Incoming packets with unknown protocol
UINT32 Out Octets Sent octets
UINT32
Out Ucast Packets
Sent Unicast packets
UINT32
Out NUcast packets
Sent non-Unicast packets
UINT32
Out Discards
Outgoing packets, not processed
UINT32
Out Errors
Outgoing packets, with errors