Operation
7.1 Operation
SINAMICS DCP
168 Operating Instructions, 09/2019, A5E34382853K
Fixed values for interconnection using BICO technology
The following connector outputs are available for interconnecting any fixed value settings:
p2900[0...n]
p2901[0...n]
p2902[0...n]
p50401
p50402
p50403
p50421 ... p50428
r52000 ... r52008
xed values
These parameters can be used for test purposes.
7.1.1.5 Data sets
CDS: Command Data Set
The BICO parameters (binector and connector inputs) are grouped together in a command
data set. These parameters are used to interconnect the signal sources of a SINAMICS
DCP.
By parameterizing several command data sets and switching between them, the SINAMICS
DCP can be operated with different preconfigured signal sources.
A command data set contains the following (examples):
● Binector inputs for control commands (digital signals)
– ON/OFF, enable signals (p0844, etc.)
A drive object can manage two command data sets.
The following parameters are available for selecting command data sets and for displaying
the currently selected command data set:
● Binector input p0810 BI: Command data set (CDS) selection
● r0836: Displays the selected data set