Operation
7.6 Communication via PROFINET IO
SINAMICS DCP
256 Operating Instructions, 09/2019, A5E34382853K
7.6.2 Establishing online operation: STARTER via PROFINET IO
Description
The following options are available for online operation via PROFINET IO:
Online operation via IP
Requirements
STARTER with Version 4.1.5 (SINAMICS DCP is only supported as of STARTER
Version 4.1.5)
CBE20
STARTER via PROFINET IO (example)
Figure 7-39 STARTER via PROFINET (example)
Procedure for establishing online operation with PROFINET
1. Assign the PG/PC a fixed, free IP address. In our example, we have selected
169.254.11.1. Set the subnet mask to 255.255.0.0.
2. Make the settings in STARTER
3. Select online operation in STARTER.