Operation
7.4 Communication according to PROFIdrive
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
197
Figure 7-16 Reading and writing data
Properties of the parameter channel
One 16-bit address exists for each parameter number and subindex.
Concurrent access by several additional PROFIBUS masters (master class 2) or
PROFINET IO Supervisor (e.g. commissioning tool).
Transfer of different parameters in one access (multiple parameter request).
Transfer of complete arrays or part of an array possible.
Only one parameter request is processed at a time for each controller/device connection
(no pipelining).
A parameter request/parameter response must fit into a data set (e.g. PROFIBUS: max.
240 bytes).
The task or response header are user data.