Operation
7.4 Communication according to PROFIdrive
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
199
Description of fields in the parameter request and response
Table 7- 21 Fields
Field
Data type
Values
Remark
Request reference
Unsigned8
01 hex ... FF hex
Unique identification of the request/response pair for the master. The master changes the
request reference with each new request. The slave mirrors the request reference in its
response.
Request ID Unsigned8 01 hex
02 hex
Read request
Write request
Specifies the type of request.
In the case of a write request, the changes are made in a volatile memory (RAM). A save
operation is needed in order to transfer the modified data to the non-volatile memory
(p0971, p0977).
Response ID Unsigned8 01 hex
02 hex
81 hex
82 hex
Read request (+)
Write request (+)
Read request (-)
Write request (-)
Mirrors the request identifier and specifies whether request execution was positive or nega-
tive.
Negative means:
Cannot execute part or all of request.
The error values are transferred instead of the values for each subresponse.
Drive object
number
Unsigned8
01 hex ... FE hex
Number
Specification of the drive object number for a drive unit with more than one drive object.
Different drive objects with separate parameter number ranges can be accessed over the
same DPV1 connection.
Number of parameters Unsigned8 01 hex ... 27 hex No. 1 ... 39
Limited by DPV1 telegram length
Defines the number of adjoining areas for the parameter address and/or parameter value
for multi-parameter requests.
The number of parameters = 1 for single requests.
Attribute Unsigned8 10 hex
20 hex
30 hex
Value
Description
Text (not implemented)
Type of parameter element accessed.
Number of elements Unsigned8 00 hex
01 hex ... 75 hex
Special function
No. 1 ... 117
Limited by DPV1 telegram length
Number of array elements accessed.
Parameter number
Unsigned16
0001 hex ... FFFF hex
No. 1 ... 65535
Addresses the parameter to be accessed.
Subindex
Unsigned16
0000 hex ... FFFF hex
No. 0 ... 65535
Addresses the first array element of the parameter to be accessed.