Operation
7.8 Communication via EtherNet/IP (EIP)
SINAMICS DCP
296 Operating Instructions, 09/2019, A5E34382853K
Table 7- 54 Identity Object – Class Attributes
Attribute ID
Service
Type
Name
1
get
UINT16
Revision
2
get
UINT16
Max Instance
3
get
UINT16
Num of Instances
Table 7- 55 Identity Object – Instance Attributes
Attribute ID
Service
Type
Name
Value
Description
1 get UINT16 Vendor ID 1251 Siemens
2
get
UINT16
Device Type
0x0C
Siemens Drive
3
get
UINT16
Product Code
5480
CU_DCP r0964[1]
4
get
Struct of
Revision
-
-
5
get
WORD
Status
...
See the following table
6 get UINT32 Serial number ... Bit 0 ... 19: Consecutive number
Bits 20 ...23: Production day
Bits 24 ... 27: Month of manufacture (0 = Jan, B =
Dec)
Bits 28 … 31: Year of manufacture (0 = 2002)
7 get SHORT_ST
RING
Product Name SINAMICS
DCP
Max. length 32 bytes
Table 7- 56 Identity Object – explanation of Instance Attribute ID 5 of the previous table
Byte
Bit
Name
Description
1 0 Owned 0: Converter is not assigned to a controller
1: Converter is assigned to a controller
1
-
Reserved
2 Configured 0: Ethernet/IP basic settings
1: modified Ethernet/IP settings
3
-
Reserved
4 … 7 Extended Device
Status
0: Self-test or status not known
1: Firmware update active
2: At least one I/O connection with error
3: No I/O connections
4: Incorrect configuration in the ROM
5: Fatal fault
6: At least one I/O connection is active
7: All I/O connections in the quiescent state
8 … 15: Reserved
2
8 … 11
-
not used
12 … 15
-
Reserved