Operation
7.8 Communication via EtherNet/IP (EIP)
SINAMICS DCP
296 Operating Instructions, 09/2019, A5E34382853K
Table 7- 54 Identity Object – Class Attributes
Table 7- 55 Identity Object – Instance Attributes
1 get UINT16 Vendor ID 1251 Siemens
6 get UINT32 Serial number ... Bit 0 ... 19: Consecutive number
Bits 20 ...23: Production day
Bits 24 ... 27: Month of manufacture (0 = Jan, B =
Dec)
Bits 28 … 31: Year of manufacture (0 = 2002)
7 get SHORT_ST
Product Name SINAMICS
Max. length 32 bytes
Table 7- 56 Identity Object – explanation of Instance Attribute ID 5 of the previous table
1 0 Owned 0: Converter is not assigned to a controller
1: Converter is assigned to a controller
2 Configured 0: Ethernet/IP basic settings
1: modified Ethernet/IP settings
4 … 7 Extended Device
Status
0: Self-test or status not known
1: Firmware update active
2: At least one I/O connection with error
3: No I/O connections
4: Incorrect configuration in the ROM
5: Fatal fault
6: At least one I/O connection is active
7: All I/O connections in the quiescent state
2