Operation
7.8 Communication via EtherNet/IP (EIP)
SINAMICS DCP
Operating Instructions, 09/2019, A5E34382853K
307
Figure 7-52 Properties
Make the following settings:
Select a name to identify the drive.
Enter the IP address of the drive
Set the "Connection Parameters" as described in Chapter "Implicit messagingcyclic
communication as I/O slave (Page 292)".
After the configuration has been activated, the drive data can be accessed via the input and
output data fields (following diagram).
For a better program documentation, it is recommended that aliases be defined for each
input and output signal.
Figure 7-53 Input data and output data
Now configure the drive in order to use EtherNet/IP.