Operation
7.16 Diagnostics
SINAMICS DCP
370 Operating Instructions, 09/2019, A5E34382853K
Note
Only those messages which are listed in the indexed parameters can be changed as
desired. All other messages retain their factory settings or are reset to the factory setti
ngs.
Examples:
•
In the case of messages listed via p2128[0...19], the message type can be changed. The
factory setting is set for all other messages.
•
The fault response of fault F12345 has been changed via p2100[n]. The factory settings
are to be restored.
– p2100[n] = 0
Triggering on messages (example)
Select message
Trigger signal
p2128[0] = 1001
BO: r2129.0
or
p2128[1] = 1002
BO: r2129.1
Note
The value from CO: r2129 can be used as a group trigger.
CO: r2129 = 0 No selected message has been ou
tput.
CO: r2129 > 0 Group trigger.
At least one selected message has been output.
The individual binector outputs BO: r2129 should be investigated.
Triggering messages externally
If the appropriate binector input is interconnected with an input signal, fault 1, 2, or 3 or alarm
1, 2, or 3 can be triggered via an external input signal.
After an external fault 1 to 3 has been triggered on the Control Unit drive object, then this
fault is also present on all associated drive objects. If one of these external faults is triggered
on a different drive object, it is only present on that particular drive object.
BI: p2106
→ External fault 1
→ F07860(A)
BI: p2107
→ External fault 2
→ F07861(A)
BI: p2108 → External fault 3 → F07862(A)
BI: p2112
→ External alarm 1
→ A07850(F)
BI: p2116 → External alarm 2 → A07851(F)
BI: p2117
→ External alarm 3
→ A07852(F)