Technical specifications
10.2 Device data
SINAMICS DCP
430 Operating Instructions, 09/2019, A5E34382853K
Variable
Value
Remark
Use Exclusively for cabinet installation
Pollution degree 2
Cooling method Forced ventilation Forced air cooling with integrated fans
The fan speed is changed as a function of the temper-
atures of the power units.
Rated fan speed
rpm
11000
Fan air flow
m
3
/h
1200
Fan noise level dB(A) 65 ... 80 The fan noise changes as a function of the fan speed,
which is controlled dependent on the temperatures of
the power units.
Power connections
- P1, N1, P2, N2
- PE
max. 95 mm²
M8 bolts, 13 Nm
M8 bolts, 13 Nm
Dimensions (W x H x D)
mm
205 x 900 x 500
Weight (approx.)
kg
118
MTBF: Expected operating time between two consecutive failures: 20 years