564 Function Manual, 01/2011, 6SL3097-4AB10-0BP3
Bit Name Signal status, description
12 Reserved -
1 Acknowledgement for Gn_STW.13 (request absolute value cyclically)
Note:
Cyclic transmission of the absolute value can be interrupted by a function
with higher priority.
See Gn_XIST2
13 Transmit absolute value
cyclically
0 No acknowledgement
1 Parking encoder active (i.e. parking encoder switched off) 14 Parking encoder
0 No active parking encoder
1 Error from encoder or actual-value sensing is active.
Note:
The error code is stored in Gn_XIST2.
15 Encoder error
0 No error is active.
Encoder 1 actual position value 1 (G1_XIST1)
Resolution: Encoder lines ∙ 2n
n: fine resolution, no. of bits for internal multiplication
The fine resolution is specified via p0418.
Used to transmit the cyclic actual position value to the controller.
The transmitted value is a relative, free-running actual value.
Any overflows must be evaluated by the master controller.
)LQHLQIRUPDWLRQ(QFRGHUSXOVHV
,QWHUQDOPXOWLSOLFDWLRQ
)DFWRU\VHWWLQJ
SIRU*[B;,67HQFRGHUWR


%LW
Figure 9-11 Subdivision and settings for Gx_XIST1
Encoder lines of incremental encoder
For encoders with sin/cos 1Vpp:
Encoder lines = no. of sinusoidal signal periods
After power-up: Gx_XIST1 = 0
An overflow in Gx_XIST1 must be viewed by the master controller.
There is no modulo interpretation of Gx_XIST1 in the drive.