EasyManuals Logo

Siemens SINAMICS S120 Combi User Manual

Siemens SINAMICS S120 Combi
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
103
External fan unit
5
5.1 Description
The S120 Combi provides an integrated fan control and supply for an external 24 V fan unit.
The fan unit is connected via interface X12/X13. The output is designed for a maximum
current of 2 A and is short-circuit and ground-fault proof.
The following functions are available when using the external fan unit:
Operating hours counter (p0251)
Setting the maximum operation time (P0252)
Evaluating fault signals

Table of Contents