DC link components 
  8.3 Braking resistors 
SINAMICS S120 Combi 
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3 
165 
8.3.4  Technical data 
Table 8- 14  Technical data for braking resistors that have no thermostatic switch  
  Unit  6SN1113–1AA00–0DA0  6SL3100–1BE31–0AAx 
Rated power P
n
  kW  0.3  1.5 
Peak power P
max
  kW  25  100 
Max. energy consumption E
max
  kWs  7.5  200 
Power cable connection    Included in scope of delivery; 
length 3 m, 3 x 1.5 mm
2
 
Screw terminal, 4 mm
2
 
Weight  kg  3.4  5.6 
Dimensions (W x H x D)  mm  80 x 210 x 53  193 x 410 x 240 
Degree of protection according 
to EN 60529 
  IP54B  IP20 
Duty cycle 
7
$$
N:N:
3
Q
3
PD[
3>N:@
W>V@
 
Figure 8-13  Duty cycle for braking resistors 
T [s] period duration of braking duty cycle 
A [s] load duration 
P
n
 [W] continuous braking power of braking resistor 
P
max
 [W] peak power of braking resistor (6 x P
N
) 
Table 8- 15  Duty cycles for Braking Module Booksize 
  6SN1113–1AA00–0DA0  6SL3100–1BE31–0AAx 
  Short duty cycle  Long duty cycle  Short duty cycle  Long duty cycle 
A [s]  0.1  0.4  1  2 
T [s]  11.5  210  68  460