DC link components
8.1 Braking Module Booksize
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
145
8.1.5 Meaning of LEDs
Table 8- 4 Meaning of the LEDs on the Braking Module Booksize
LED Color Status Description, cause Remedy
- Off Electronics power supply is missing or outside permissible
tolerance range.
Component deactivated via terminal.
Green Continuous
light
Component is ready to operate.
READY
Red Continuous
light
Enable missing (input terminal)
Overtemperature
Overcurrent trip
I
2
t monitoring activated
Ground fault/short circuit
Note:
In the event of an overtemperature, the error cannot be
acknowledged until a cooling time has elapsed.
Diagnose fault (via
output terminals) and
acknowledge it (via
input terminal)
- Off Only braking resistors approved by Siemens for this
component are identified automatically.
Component not active.
DC LINK
Green Flashing
light
Component active (DC link discharge via braking resistor in
progress).