Encoder system connection
11.1 Sensor Module Cabinet-Mounted SMC20
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
213
11.1.6 Technical data
Table 11- 5 Technical data
6SL3055-0AA00-5BAx Unit Value
Electronics power supply
Voltage
Current (without encoder system)
Current (with encoder system)
Power loss
V
DC
A
DC
A
DC
W
24 DC (20.4 – 28.8)
≤ 0.20
≤ 0.35
≤ 10
Encoder system power supply
Voltage
Current
V
encoder
A
encoder
5 V DC (with Remote Sense)
1)
0.35
Encoder frequency that can be evaluated
(f
encoder
)
kHz ≤ 500
SSI baud rate
2)
kHz 100 - 250
Max. encoder cable length m 100
PE/ground connection At the housing with M4/1.8 Nm screw
Weight kg 0.45
Degree of protection IP20 or IPXXB
1) A controller compares the encoder system supply voltage - sensed via the Remote Sense cables - with the reference
supply voltage of the encoder system, and adjusts the supply voltage for the encoder system at the output of the sensor
module until the required supply voltage is obtained directly at the encoder system (only for 5 V encoder system power
supply).
2) Only possible for SSI encoders with 5 V supply
Note
Current controller clock cycle
For a current controller clock cycle of 31.25 µs, an SMC20 with order number 6SL3055-
0AA00-5BA3 must be used.