Encoder system connection
11.3 Sensor Module External SME25
SINAMICS S120 Combi
222 Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
11.3 Sensor Module External SME25
11.3.1 Description
Direct encoder systems outside the cabinet can be connected to the Sensor Module External
SME25. The SME25 evaluates these encoder systems and converts the calculated values to
DRIVE-CLiQ.
Direct encoder systems with EnDat 2.1 or SSI with SIN/COS (1 Vpp) incremental signals can
be connected, however without reference signal.
Neither motor nor encoder data are saved in the SME25.
11.3.2 Interface description
11.3.2.1 Overview
(QFRGHUV\VWHPLQWHUIDFH
SLQ
3URWHFWLYHFRQGXFWRUFRQQHFWLRQ
01P
'5,9(&/L4
,QWHUIDFH
Figure 11-9 Interface description SME25