Motor Modules Booksize Compact as expansion axes   
7.3 Interface description 
  SINAMICS S120 Combi 
126  Manual, Edition 07/2012, 6SL3097-4AV00-0BP3 
Parameters p9651 and p9851 are used to set the filter times for the debouncing of terminals 
X21.3 and X21.4, as well as X22.3 and X22.4. Additional parameter settings are also 
required in order to prevent discrepancy errors when performing bit pattern tests (light/dark 
tests). For comprehensive information, see the SINAMICS S120 Safety Integrated Function 
Manual, Chapter 6 "Controlling the safety functions". 
 
NOTICE 
 
The KTY temperature sensor must be connected with the correct polarity. 
If the polarity is reversed, the sensor will not be able to detect if the motor overheats. 
 
 
Note 
The temperature sensor input is not needed if the motors feature an integrated DRIVE-CLiQ 
interface or if temperature values are detected by means of a different module (SMC, SME).
 
 
DANGER 
 
Risk of electric shock! 
Only temperature sensors that meet the safety isolation specifications contained in 
EN 61800-5-1 may be connected to terminals "+Temp" and "-Temp". 
If these instructions are not complied with, there is a risk of electric shock! 
 
7.3.5  X200-X203 DRIVE-CLiQ interface 
Table 7- 4  X200-X202: DRIVE-CLiQ interfaces for Single Motor Modules 
X200-X203: DRIVE-CLiQ interfaces for Double Motor Modules 
  Pin  Name  Technical specifications 
1  TXP  Transmit data + 
2  TXN  Transmit data - 
3  RXP  Receive data + 
4  Reserved, do not use   
5  Reserved, do not use   
6  RXN  Receive data - 
7  Reserved, do not use   
8  Reserved, do not use   
A  + (24 V)  Power supply 
 
 
B  M (0 V)  Electronics ground 
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery. 
Blanking cover (50 pcs.) Order number: 6SL3066-4CA00-0AA0